Square D™ EGB26070 Type EGB Circuit Breaker, 600Y/347 VAC VAC, 70 A, 65 kA at 240 VAC/35 kA at 480Y/277 VAC Interrupt, 2 Poles, Thermal/Magnetic Trip

Lighting Panel Circuit Breakers
PDW~6399483 MFG #: EGB26070
Square D™
0.00000 / ea
  • Alternate Catalog Number: EGB26070
  • Amperage Rating: 70 A
  • Application: For overload and short circuit protection
  • ARRA Compliant: N
  • Brand: Square D™
  • Buy American Compliant: N
  • Catalog Number: EGB26070
  • Connection: LUGS: (1) 14 AWG-2/0 AL OR CU
  • Connection Type: Lug
  • Country of Origin: US
  • Currency: USD
  • Depth: 4.05 in
  • Dimensions: 5.66 in H x 1.96 in W x 4.05 in D
  • Enclosure: NF PANELBOARD
  • EU RoHS Indicator: Y
  • Frame: E-FRAME
  • Frequency Rating: 50/60 Hz
  • Gross Weight Per Pack: 0.0114 lb
  • Gross Weight per Pack Metric: 1.15
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536200020
  • Height: 9.3980 in
  • Height [Metric]: 9.3980 cm
  • Interrupt Rating: 65 KAIC @ 240 VAC 35 KAIC @ 480 VAC
  • Item Group: 00936
  • Length: 24.8920 in
  • Length [Metric]: 24.8920 cm
  • Manufacturer: Schneider Electric
  • Material: Thermoset Composite Resin
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=397399&lang=en-us
  • Mounting Type: Bolt-On
  • Number Of Poles: 2
  • Operating Temperature: CALIBRATED FOR USE AT 40 DEGREES C. SEE DATA BULLETIN 0100DB0101 FOR RE-RATING INFORMATION.
  • Phase: 1
  • Returnable: Y
  • Standard: UL LISTED - CSA CERTIFIED
  • Sub Brand: NF BRANCH CIRCUIT BREAKERS (BOLT-ON)
  • Temperature Rating: 104
  • Trip Range: HTTP://CISNT06.C076.US.SCHNEIDER-ELECTRIC.COM/PUBS/CIRCUIT20PROTECTION/MOLDED20CASE20CIRCUIT20BREAKERS/012520A20FRAME20EDB-EGB-EJB/515-4.PDF A
  • Trip Type: Thermal Magnetic
  • Type: MOLDED CASE CIRCUIT BREAKER
  • UNSPSC: 39121603
  • UPC 11: 78590149803
  • UPC 12: 785901498032
  • Voltage Rating: 347/600 VAC
  • Warranty Description: Contractual Warranty:18 months
  • Width: 15.2400 in
  • Width [Metric]: 15.2400 cm
  • Wire Size: 12 to 2/0 AWG Al, 14 to 2/0 AWG Cu
Square D™ Circuit Breaker, Type EGB, 600Y/347 VAC VAC, 70 A, 50/60 Hz Frequency, 65 kA at 240 VAC/35 kA at 480Y/277 VAC Interrupt, E Frame, Thermal/Magnetic Trip, 630 to 1800 A Trip, 2 Pole, 1 ph ph, Lug Connection, 12 to 2/0 AWG Al, 14 to 2/0 AWG Cu Wire, Bolted-On Mounting, 104 deg F, 5.66 in H x 1.96 in W x 4.05 in D Dimensions, Thermoset Composite Resin
QTY
  • Applications
  • Features
For overload and short circuit protection
BOLT-ON