Bussmann® LPJ-90SP Low-Peak™ LPJ Current Limiting Time Delay Fuse, 90 A, 600 VAC/300 VDC, 300/100 kA Interrupt, Class J Series
Class J Fuses
5231
MFG #: LPJ-90SP
Bussmann
118.91000
/ ea
- Alternate Catalog Number: LPJ-90SP
- Application: Ind Facilities & Factories - Facility: Safety and Security Systems
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: LPJ-90SP
- Connection: Bolted Blade End X Bolted Blade End
- Country of Origin: MUL
- Currency: USD
- Element: Dual
- EU RoHS Indicator: C
- Gross Weight Per Pack: 0.2650 lb
- Gross Weight per Pack Metric: 0.14
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536100040
- Height: 4.63 in
- Height [Metric]: 11.7602 cm
- Length: 1.13 in
- Length [Metric]: 2.8702 cm
- Response Time: 10 sec at 500%
- Returnable: Y
- Size: 1.13 In Diameter X 4.63 In Length
- Standard: CE Marked,RoHS Compliant
- Standards: UL Listed Guide No. JDDZ, File No. E4273, CSA Class 1422-02, File No. 53787, CSA C22.2 No. 248.8, CE Certified, RoHS compliant
- Sub Brand: Bussmann Series
- Type: Fuse
- UNSPSC: 39121626
- UPC 11: 05171252339
- UPC 12: 051712523394
- Width: 1.13 in
- Width [Metric]: 2.8702 cm
- Stock Status: NORMALLY STOCKED
- Brand: Bussmann
- Manufacturer: Eaton
- Amperage Rating: 90 A
- Class: J
- Interrupt Rating: 100 kAIC Vdc300 kAIC at 600 Vac
- Voltage Rating: 600//300 VAC//VDC
Bussmann series Ultimate protection LPJ Class J dual element, current- limiting time-delay fuses available with optional open fuse indication. time-delay - 10 seconds (minimum) at 500% of rated current.
- Brochure URL - COBUSSE01827_23.pdf(Brochure URL)
- http://www.bussmann.com(Seller Home Page URL)
- Spec Sheet 1 URL - Bussmann_LPJ_350SP_Specification_Sheet_1.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 10973_2T8K9WEDIALONB3Z.pdf(Spec Sheet URL)
- Spec Sheet URL - LPJ-90SP(Spec Sheet URL)
- Spec Sheet URL - skuPage.LPJ-90SP.pdf(Spec Sheet URL)
- Tech Bulletin URL - datasheet.php?model=FNQ-30&locale=en_GB(Tech Bulletin URL)
- Tech Drawing URL - Bus_Ele_DS_1007_LPJ_70-600.pdf(Tech Drawing URL)
- Video - https://www.youtube.com/embed/YMvqUyoETXk(Video)
- Applications
- Features
Ind Facilities & Factories - Facility: Safety and Security Systems |
Non-indicating, High in-rush current motor protection |
Separate overload and short circuit elements provide time delay for sizing of high inrush loads linked with Class J current limitation |
Selective coordination ratio of 2: 1 (within low peak fuse family) prevents electrical shutdowns from extending beyond the failed circuit |
Series combination ratings with branch circuit breakers allows broad range of coverage, independent of breaker manufacturer |
Proper sizing can provide "no damage" Type 2 coordinated protection for NEMA and IEC motor controller |
Space-saving package for equipment downsizing |
Industry's only UL Listed and CSA Certified fuse with a 300kA interrupting rating that allows for simple, worry-free installation in virtually any application |
Fast short circuit protection and dual-element, time-delay performance provide ultimate protection |
Reduces existing fuse inventory by up to 33% when upgrading to low peak fuses |
Consistent 2:1 ampacity ratios for all low peak fuses make selective coordination easy |
Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges |
Current-limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents |
Dual-element fuses have lower resistance than ordinary fuses so they run cooler |
They can often be sized for back-up protection against motor burnout from overload or single phasing if other overload protective devices fail |
300 kA at 600 VAC RMS sym |