Bussmann® FRS-R-110 Fusetron™ FRS-R Current Limiting Time Delay Fuse, 110 A, 600 VAC/300 VDC, 200/20 kA Interrupt, Class RK5

Class RK5 Fuses
5153 MFG #: FRS-R-110
Bussmann
153.96000 / ea
  • Alternate Catalog Number: FRS-R-110
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Body Size: 1.61 in Dia x 9.63 in L
  • Buy American Compliant: C
  • Catalog Number: FRS-R-110
  • Connection: Blade end x blade end
  • Country of Origin: MX
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 1.0500 lb
  • Gross Weight per Pack Metric: 0.48
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 9.63 in
  • Height [Metric]: 24.4602 cm
  • Length: 5.00 in
  • Length [Metric]: 12.7000 cm
  • Material: Fiberglass
  • Mounting Type: Holder
  • Response Time: 10 S at 500%
  • Series: FRS-R
  • Size: 1.61 In Diameter X 9.63 In Length
  • Standard: CE Marked
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCE CertifiedUL 248-12 File No. E4273 Guide JDDZCSA File No. 53787 C22.2 No. 248.12 Class 1422-02
  • Sub Brand: Bussmann Series
  • Terminal Type: Knife Blade
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171250844
  • UPC 12: 051712508445
  • Width: 1.61 In
  • Width [Metric]: 4.0894 cm
  • Stock Status: NONSTOCK
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 110 A
  • Class: RK-5
  • Interrupt Rating: 20 kAIC at 300 Vdc200 kAIC at 600 Vac
  • Voltage Rating: 600//300 VAC//VDC
Time-delay affords the same excellent overload protection as low peak fuses of motors and other type loads and circuits having temporary inrush currents such as those caused by transformers and solenoids. (In such circuits, Limitron fuses can only provide short circuit protection). Fusetron fuses are not as Fast-Acting on short circuits as low peak fuses and therefore cannot give as high a degree of componet short circuit protection. Like the low peak fuse, Fusetron fuses permit the use of smaller size and less costly switches. Fusetron fuses fit rejection type fuse holders and can also be installed in holders for Class H fuses. They can physically and electrically replace Class H, K5, and other Class RK5 fuses.
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Renewable
Without open fuse indication
Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
Offers a 10 sec time delay at 5 times the rated current
The time-delay feature makes it possible to use fuse amp ratings that are much smaller than those of non-time delay fuses
Provides a good deg of short circuit protection (greater current limitation) to help protect downstream components from high fault currents
Gives motor running back-up protection to motors without extra cost
Helps protect motors against burnout from overloads and single phasing when sized properly
Simplifies and improves blackout prevention (selective coordination ratios)