Bussmann® FRS-R-6 Fusetron™ FRS-R Time Delay Fuse, 6 A, 600 VAC/300 VDC, 200 kA VAC RMS Sym/20 kA VDC Interrupt, Class RK5

Class RK5 Fuses
5165 MFG #: FRS-R-6
Bussmann
24.20000 / ea
  • Alternate Catalog Number: FRS-R-6
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Body Size: 13/16 in Dia x 5 in L
  • Buy American Compliant: C
  • Catalog Number: FRS-R-6
  • Connection: Ferrule end x ferrule end
  • Country of Origin: MX
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.2100 lb
  • Gross Weight per Pack Metric: 0.07
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 5.00 in
  • Height [Metric]: 12.7000 cm
  • Length: 5.00 in
  • Length [Metric]: 12.7000 cm
  • Material: Fiberglass
  • Mounting Type: Holder
  • Response Time: 10 S at 500%
  • Series: FRS-R
  • Size: 0.81 In Diameter X 5.00 In Length
  • Standard: CE Marked
  • Sub Brand: Bussmann Series
  • Terminal Type: Clip
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171250857
  • UPC 12: 051712508575
  • Width: 0.81 in
  • Width [Metric]: 2.0574 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 6 A
  • Class: RK-5
  • Interrupt Rating: 200 kAIC at 600 Vac20 kAIC at 300 Vdc
  • Voltage Rating: 600//300 VAC//VDC
Advanced protection, energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional open fuse indication on select ratings. Time-delay 10 second (minimum) at 500% of rated current.
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Renewable
Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
Offers a 10-second time delay at 5 times the rated current
The time delay feature makes it possible to use fuse amp ratings that are much smaller than those of non-time delay fuses, considerable cost savings occur by permitting the use of smaller size switches, panels, and fuses themselves
Provides current limitation to help protect downstream components from high fault currents
Gives motor running back-up protection to motors without extra costs
Dual-element feature provides the best time delay performance, allowing closer sizing and superior protection of motors and transformers
Closer sizing allows for smaller fuses and less costly switches
Class RK5 fuses with a 200 kA interrupting rating for use in a broad range of applications
Provides motor overload, ground fault, and short circuit protection
Helps protect motors against burnout from overloads and single-phasing when sized properly