Schneider Electric Altivar 71 ATV71HU40N4 Variable Speed Drive With Heat Sink, 380/480 VAC, 11.5/14.1 A, 5 hp, 6.1 in W

AC Variable Frequency Drives
402373 MFG #: ATV71HU40N4
Schneider Electric
2576.03000 / ea
  • Application: 4 KW, 3 PHASE 380...480 V,5 HP, 3 PHASE 380...480 V,ASYNCHRONOUS MOTORS-SYNCHRONOUS MOTORS,COMPLEX, HIGH-POWER MACHINES
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: ATV71HU40N4
  • Control: +/- 0.01 OF NOMINAL SPEED IN CLOSED-LOOP MODE WITH ENCODER FEEDBACK 0.2 TN TO TN-+/- 10 OF NOMINAL SLIP WITHOUT SPEED FEEDBACK 0.2 TN TO TN
  • Country of Origin: ID
  • Display: DRIVE VOLTAGE 1 LED RED)
  • Display Type: Analog
  • Enclosure: IP20
  • Enclosure Type: IP20
  • Environmental Conditions: -10-50 A°C WITHOUT)
  • EU RoHS Indicator: Y
  • Gross Weight Per Pack: 13.3000 lb
  • Harmonization Tariff Schedule Code: 8504404000
  • Height: 10.24 in
  • Item Group: 22130
  • Returnable: Y
  • Size: 155 MM,187 MM,260 MM
  • Standards: UL Listed, NOM 117, CSA, C-Tick, GOST, CE Certified, RoHS Compliant
  • Sub Brand: ALTIVAR 71
  • Type: Variable speed drive
  • UNSPSC: 39122001
  • UPC 11: 78590169167
  • UPC 12: 785901691679
  • Stock Status: NONSTOCK
  • Brand: Schneider Electric
  • Manufacturer: Schneider Electric
  • Amperage Rating: 11.5/14.1 A
  • Depth: 7.36 in
  • Horsepower: 5 hp
  • Voltage Rating: 380/480 VAC
  • Width: 6.1 in
Schneider Electric ATV71HU40N4 SPEED DRIVE, 5HP, 460V, ATV71,3 phases,3-Phase,3-Phase,400/480VAC,4kW,Altivar 71,Altivar 71,IP20,Modbus-CANopen,Modbus-CANopen,complex, high-power machines,variable speed drive
QTY
  • Applications
  • Features
4 KW, 3 PHASE 380...480 V,5 HP, 3 PHASE 380...480 V,ASYNCHRONOUS MOTORS-SYNCHRONOUS MOTORS,COMPLEX, HIGH-POWER MACHINES
ADJUSTABLE PI REGULATOR,AGAINST EXCEEDING LIMIT SPEED DRIVE-SHORT-CIRCUIT BETWEEN MOTOR PHASES DRIVE-THERMAL PROTECTION DRIVE-MOTOR PHASE BREAK MOTOR-POWER REMOVAL MOTOR-THERMAL PROTECTION MOTOR-AGAINST INPUT PHASE LOSS DRIVE-BREAK ON THE CONTROL CIRCUIT DRIVE-INPUT PHASE BREAKS DRIVE-LINE SUPPLY OVERVOLTAGE DRIVE-LINE SUPPLY UNDERVOLTAGE DRIVE-OVERCURRENT BETWEEN OUTPUT PHASES AND EARTH DRIVE-OVERHEATING PROTECTION DRIVE-OVERVOLTAGES ON THE DC BUS DRIVE,FLUX VECTOR CONTROL (FVC) WITH SENSOR (CURRENT VECTOR)-ENA (ENERGY ADAPTATION) SYSTEM FOR UNBALANCED LOADS-SENSORLESS FLUX VECTOR CONTROL (SFVC) (VOLTAGE OR CURRENT VECTOR)-VOLTAGE/FREQUENCY RATIO (2 OR 5 POINTS),INTERNAL SUPPLY FOR REFERENCE POTENTIOMETER (1 TO 10 KOHM) 10.5 V DC +/- 5 , <10 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION-INTERNAL SUPPLY 24 V DC 21-27 V), <200 MA OVERLOAD AND SHORT-CIRCUIT PROTECTION,TERMINAL 2.5 MMA², AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)-TERMINAL 4 MMA², AWG 10 L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
4 kW motor power
3-phase
50/60 Hz supply frequency
9.3 kVA apparent power
10.5/7.6 A nominal output current
0.1/599 Hz output frequency
4 kHz nominal switching frequency
1/16 kHz adjustable switching frequency
4/16 kHz with derating factor switching frequency
47.5 to 63 Hz network frequency
54.5 dB noise level
1/100 in open-loop mode, without speed feedback speed range
1/50 in open-loop mode, without speed feedback speed range
1/1000 in open-loop mode, without speed feedback speed range