Telemecanique XMLR016G0T25 XMLR Series Fixed Differential, Pressure Sensor sensing, 10 ms response, Analogue output, 24 VDC

Pressure Sensors
PDW~11800603 MFG #: XMLR016G0T25
Telemecanique Sensors
318.00000 / ea
  • Alternate Catalog Number: XMLR016G0T25
  • Application: For accurate pressure measurement and display
  • ARRA Compliant: N
  • Brand: Telemecanique Sensors
  • Buy American Compliant: N
  • Catalog Number: XMLR016G0T25
  • Country of Origin: CH
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 41.30
  • Gross Volume per Pack Metric: 676.78
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 0.4200 lb
  • Gross Weight per Pack Metric: 190.00
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 9026204000
  • Item Group: 21551
  • Manufacturer: Telemecanique Sensors
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=347330651&lang=en-us
  • Returnable: N
  • Substitute Product Catalog Number: XZCP1241L2
  • Type: Pressure transmitter;Electronic pressure sensors
  • UNSPSC: 41111927
Telemecanique XMLR016G0T25, Fixed Differential, XMLR Series, Pressure Sensor Sensing Method, 10 ms Response, Analogue Output, 24 VDC, 50 mA, Male connector Connection, 232.06 psi Pressure, 3.66 in H x 1.61 in W x 1.65 in D Size, IP65/IP67 Enclosure, -20 to 80 deg C Operating, Environmental Conditions: -40 to 176
QTY
  • Applications
  • Features
For accurate pressure measurement and display
Polyester front material
0.5 kV DC uimp rated impulse withstand voltage
Fresh water 32 to 176 deg F (0 to 80 deg C))Air -4 to 176 deg F (-20 to 80 deg C))Hydraulic oil -4 to 176 deg F (-20 to 80 deg C))Refrigeration fluid -4 to 176 deg F (-20 to 80 deg C)) controlled fluid
Polyacrylamide 316L stainless steel housing material
Overload protection, Reverse polarity, Overvoltage protection, Short-circuit protection type
4 digits 7 segments display type
Fast 50 msNormal 200 msSlow 600 ms display response time type
300 ms maximum delay first up
<= 1 % of the measuring range overall accuracy
<= 0.2 % of the measuring range hysteresis on analogue output
<= 0.2 % of the measuring range hysteresis on analogue output
<= 0.6 % of the measuring range measurement accuracy on switching output
+/- 03 % of measuring range/ deg C drift of the sensitivity
+/- 0.1 % of measuring range/ deg C drift of the zero point
<= 1 % of the measuring range display accuracy
10000000 cycles mechanical durability