Telemecanique XMLR160M2P09 XMLR Series Fixed Differential, Pressure Sensor sensing, 5 ms response, Solid State/PNP output, 24 VDC
Pressure Sensors
PDW~11800654
MFG #: XMLR160M2P09
Telemecanique Sensors
704.25000
/ ea
- Alternate Catalog Number: XMLR160M2P09
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: XMLR160M2P09
- Connection: Male connector M12, 4 pins
- Country of Origin: CH
- Currency: USD
- EU RoHS Indicator: Y
- Gross Volume Per Pack: 81.79
- Gross Volume per Pack Metric: 1340.29
- Gross Volume UOM: CI
- Gross Volume UOM Metric: cm3
- Gross Weight Per Pack: 0.4000 lb
- Gross Weight per Pack Metric: 181.00
- Gross Weight UOM Metric: g
- Harmonization Tariff Schedule Code: 9032200000
- Height: 6.5000 in
- Height [Metric]: 6.5000 cm
- Item Group: 21551
- Length: 12.7000 in
- Length [Metric]: 12.7000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=347330724&lang=en-us
- Output: Discrete;Solid state PNP, 2 NO/NC programmable
- Returnable: N
- Type: Pressure transmitter;Electronic pressure sensors
- UNSPSC: 41111927
- Width: 7.5000 in
- Width [Metric]: 7.5000 cm
- Brand: Telemecanique Sensors
- Manufacturer: Telemecanique Sensors
- Voltage Rating: 24 V DC SELV 17-33 V)
Telemecanique XMLR160M2P09, Fixed Differential, XMLR Series, Pressure Sensor Sensing Method, 5 ms Response, Solid State/PNP Output, 24 VDC, 50 mA, Male connector Connection, (2) Yellow LED Light Source, 145.04 psi Pressure, 3.70 in H x 1.61 in W x 1.65 in D Size, IP65/IP67 Enclosure, -20 to 80 deg C Operating, Environmental Conditions: -40 to 176
- Brochure URL - d5688241de64620e1ac3824440c0596c9e43a995.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADID0003810_2D-left.dxf(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_XJNCKHB127RULYQD.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Spec Sheet URL - 11003_ADVXQCSBR0TEO6NJ.pdf(Spec Sheet URL)
- Features
Polyester front material |
0.5 kV DC uimp rated impulse withstand voltage |
Fresh water 32 to 176 deg F (0 to 80 deg C))Air -4 to 176 deg F (-20 to 80 deg C))Hydraulic oil -4 to 176 deg F (-20 to 80 deg C))Refrigeration fluid -4 to 176 deg F (-20 to 80 deg C)) controlled fluid |
186 to 2320 psi (1282.42 to 15995.84 kPa)185.65 to 2320.60 psi (12.8 to 160 bar)1.28 to 16 MPa adjustable range of switching point on rising pressure |
69.62 psi (4.8 bar)0.48 MPa69.6 psi (479.88 kPa) minimum differential travel |
Polyacrylamide 316L stainless steel housing material |
Any position, but disposals can falsified the measurement in case of upside down mounting operating position |
Overload protection, Reverse polarity, Overvoltage protection, Short-circuit protection type |
0 to 50 s in steps of 1 second switching output time delay |
Fast 50 msNormal 200 msSlow 600 ms display response time type |
Fast 50 msNormal 200 msSlow 600 ms display response time type |
300 ms maximum delay first up |
<= 1 % of the measuring range overall accuracy |
<= 0.6 % of the measuring range measurement accuracy on switching output |
+/- 03 % of measuring range/ deg C drift of the sensitivity |
+/- 0.1 % of measuring range/ deg C drift of the zero point |
<= 1 % of the measuring range display accuracy |
10000000 cycles mechanical durability |