Fluke® FLUKE-289/FVF Digital Multimeter Kit With Software, 7 Pieces
Multimeters
389855
MFG #: FLUKE-289/FVF
Fluke®
1084.99000
/ ea
- Alternate Catalog Number: 3036206
- Amperage Rating: 10 A
- Application: Solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment
- ARRA Compliant: C
- Battery: 6 AA Alkaline batteries, NEDA 15A IEC LR6 V
- Buy American Compliant: C
- Capacitance: 1 nF to 100 mF Farad
- Catalog Number: FLUKE-289/FVF
- Country of Origin: US
- Currency: USD
- Dimensions: 12.2 x 10.63 x 3.94 in
- Diode Test: Yes
- Display: 50,000 count
- Display Type: VGA Dot Matrix
- Enclosure: Hard Plastic
- EU RoHS Indicator: U
- Frequency Rating: 999.99k Hz
- Gross Weight Per Pack: 2.9900 lb
- Gross Weight per Pack Metric: 1.36
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 9030310000
- Height: 10.83 in
- Height [Metric]: 27.5082 cm
- Length: 3.58 in
- Length [Metric]: 9.0932 cm
- Material: Hard Plastic
- Model: Fluke 289/FVF Kit
- Peak Hold: Yes
- Resistance: 50 O to 500 MO Ohm
- Safety Rating: CAT IV 600 VAC/VDC/CAT III 1000 VAC/VDC
- Standard: Overvoltage category: CAT III 1000 V / CAT IV 600 V; Agency approvals: CSA, UL, TÜV, CE
- Standards: ARRA CompliantBuy American Act CompliantCE MarkedCSA CertifiedTUV ApprovedUL ListedECCN 3A992PROP65: This product is in compliance with PROP65; it is not known to contain any chemicals associated with this regulation.
- Temperature Rating: -200.0 ?°C to 1350.0 ?°C (-328.0 ?°F to 2462.0 ?°F) °F
- Type: Digital Multimeter
- UNSPSC: 41113630
- UPC 11: 09596941714
- UPC 12: 095969417143
- Voltage Rating: 1k V
- Width: 12.20 in
- Width [Metric]: 30.9880 cm
- Stock Status: NONSTOCK
- Brand: Fluke®
- Manufacturer: Fluke Corporation
Maximize productivity with the combined Fluke 289 and FlukeView forms combo kit. With built-in data logger and TrendCapture capability, the 289 helps you track down elusive, intermittent problems, monitoring equipment with any of its functions while you do other jobs. Overlay your logged data from six meters or six time periods to find cause and effect relationships or for condition monitoring applications in FVF software. Turn your data into meaningful graphs and tables for a professional report. The 289/FVF combo kit gives you a practical & affordable approach to predictive maintenance.
- Catalog URL - IDW_DOCUMENT_1520602012787.pdf(Catalog URL)
- http://www.fluke.com(Seller Home Page URL)
- Install Instructions URL - ID-INS-FLUKE-289_FVF.pdf(Install Instructions URL)
- Owners Manual URL - 11095_4DRWYJGH1IUC96LO.jpg(Owners Manual URL)
- Spec Sheet URL - 11095_FLUKE-289-FVF.pdf(Spec Sheet URL)
- Applications
- Features
Solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment |
TrendCapture quickly graphically displays logged data session to quickly determine whether anomalies may have occurred |
Zoom on trend provides unprecedented ability to view and analyze TrendCapture data, zoom in up to 14 times |
Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy |
Adjustable recording and auto-hold thresholds, specify a percentage change in the readings that begins a new event |
Large 50000 count, 1/4 VGA display with white backlight, multiple sets of measurement information can be simultaneously displayed at the same time, hard plastic enclosure |
Logging function with expanded memory for unattended monitoring of signals over time, using on board TrendCapture users can graphically review logged readings without needing a PC |
Stores up to 15000 recorded events, on board help screens for measurement function |
Saved measurements allow to name and recall measurements made in the field, real time clock for automatic time stamping of saved readings |
CAT IV 600 V, CAT III 1000 V safety rating, 50000 count, 1/4 VGA display with white backlight, -200 to 1350 deg C temperature |
True-RMS AC voltage and current for accurate measurements on complex signals or non-linear loads, AC bandwidth specified to 100 kHz, 6 AA alkaline batteries, NEDA 15A IECLR6, voltage DC, 0.025%, voltage AC, 0.4% (True-RMS) |
Relative mode to remove test lead resistance from low Ohm or capacitance measurements |
Resistance range - 500 Ohm, 5 kOhm, 50 kOhm, 500 kOhm, 5 MOhm, 50 MOhm, 500 MOhm with accuracy of +/- 0.05% |
Capacitance range 1 nF, 10 nF, 100 nF, 1 uF, 10 uF, 100uF, 1000 uF, 10 mF, 100 mF with accuracy of 1% |
Frequency range 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz with accuracy of +/-0.005% |
100 hr min, 200 hr in logging mode |
Optional infrared connector via Fluke® IR3000 FC |
Capacitance range 1 nF, 10 nF, 100 nF, 1 uF, 10 uF, 100uF, 1000 uF, 10 mF, 100 mF with accuracy of 1% |
Frequency range 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz with accuracy of +/- 0.005% |
100 hrs minimum, 200 hrs in logging mode |
Optional infrared connector via Fluke ir3000 FC |