ACME AE060750 TFMR 1PH .75KVA 240X480-120/115/110

Control Transformers
539687 MFG #: AE060750
Acme Electric
153.62000 / ea
  • Application: Open Core & Coil
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: AE060750
  • Connection Type: Lead Wire/Screw
  • Country of Origin: CN
  • Currency: USD
  • Dimensions: 6.81 in H x 5.25 in W x 4.66 in D
  • Enclosure Type: NEMA 3R
  • Gross Weight Per Pack: 26.0000 lb
  • Gross Weight per Pack Metric: 11.79
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8504314065
  • Height: 4.66 in
  • Height [Metric]: 11.8364 cm
  • Housing Material: Steel
  • Insulation: Class A/105 deg C
  • Length: 6.81 in
  • Length [Metric]: 17.2974 cm
  • Mounting: Floor
  • Mounting Type: Panel
  • Number Of Phases: 1
  • Returnable: N
  • Series: AE Series
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL ListedcUL ListedCE Certified
  • Temperature Rating: 55 °C
  • Type: Industrial
  • UNSPSC: 39121026
  • UPC 11: 04750308690
  • UPC 12: 047503086902
  • Width: 5.25 in
  • Width [Metric]: 13.3350 cm
  • Stock Status: NONSTOCK
  • Brand: Acme Electric
  • Manufacturer: Acme Electric
  • Frequency Rating: 50/60 Hz
  • Phase: 1
  • Power Rating: 750 VA
  • Primary Voltage: 240/480 VAC
  • Secondary Voltage: 120 VAC
TRANSFORMER 1PH .75KVA 240X480-120/115/110
QTY
  • Applications
  • Features
Open Core & Coil
750
Epoxy encapsulated design protects core and coil assembly from potentially damaging contaminants
Integrally molded terminal blocks with isolation barriers to prevent arc over, terminal blocks allow full access for ring terminals for easy installation and solid termination
Heavy gauge steel mounting feet
Available factory or field installed fuse blocks provide integral fusing on the primary or primary and secondary
Dual labeling for easy product identification when equipped with a fuse block
0.31 x 0.69 in mounting slot
Encapsulated core and coil
These transformers have the ability to handle potentially damaging high in-rush currents that occur when electromagnetic components are energized, without sacrificing the required stable output voltage
Transformer enclosure temperature shall not exceed 65 deg C plus the ambient
Transformer shall incorporate an electrostatic shield for the attenuation of voltage spikes, line noise and transients
Transformer coils are typically wound with aluminum or copper for increased insulation life, cooler operation and lower losses
The AE and CE series design improves the dissipation of the heat away from the core and coil assembly providing cooler operation
In addition, the AE and CE series industrial control transformers seal the transformer's windings and internal terminations within an epoxy encapsulated encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants
240 x 480, 230 x 460, 220 x 440 VAC primary voltage
120/115/110 VAC secondary voltage
Furthermore, acme compact design helps minimize the mounting footprint, providing more flexibility in applications where space is a premium