Acme Electric® TB32403 TB Series Industrial Open Style Control Transformer, 240/416/480/600 VAC Primary, 50 VA, 50/60 Hz

Control Transformers
1333582 MFG #: TB32403
Acme Electric
118.60000 / ea
  • Application: Open Core & Coil
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: TB32403
  • Country of Origin: CN
  • Gross Weight Per Pack: 5.0000 lb
  • Gross Weight per Pack Metric: 2.27
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8504314065
  • Height: 3.40 in
  • Height [Metric]: 8.6360 cm
  • Length: 4.08 in
  • Length [Metric]: 10.3632 cm
  • Mounting: Floor
  • Number Of Phases: 1
  • Returnable: N
  • Standard: UL 506, UL File Number E79947V1, UL Control Number 50B8, UL Insulation Number B3223, CSA Certified, OSHA Compliant, ANSI, IEEE
  • Standards: UL Listed, CSA Certified, ANSI Approved, OSHA Approved
  • Type: Industrial Control
  • UNSPSC: 39121026
  • UPC 11: 04750300128
  • UPC 12: 047503001288
  • Width: 3.75 in
  • Width [Metric]: 9.5250 cm
  • Stock Status: NONSTOCK
  • Brand: Acme Electric
  • Manufacturer: Acme Electric
  • Frequency Rating: 50/60 Hz
  • Phase: 1 pH
  • Primary Voltage: 208/500 X 220/380/440/550 X 230/400/460/575 X 240/416/480/600 V
  • Secondary Voltage: 85/100/110 X 91/110/120 X 95/115/125 X 99/120/130 V
Acme TB Series Industrial Control Transformers are especially designed to accommodate the momentary current inrush caused when electromagnetic components are energized without sacrificing secondary voltage stability beyond practical limits. Acme TB Series transformers are dry-type, step-down transformers with the secondary control circuit isolated from the primary line circuit to assure maximum safety. Voltage regulation of Acme TB Series transformers exceeds standards recommended by the National Electrical Manufacturers Association. Secondary circuit voltage drop between no-load and momentary overload remains exceptionally low. This excellent secondary circuit voltage regulation assures reliable operation of electromagnetic components and may permit the use of a smaller and less expensive industrial control transformer.
QTY
  • Applications
  • Features
Open Core & Coil
50 VA
Constructed with high quality silicon steel lamination to minimize core losses and increase efficiency
Designs incorporate precision split bobbin wound coils for improved regulation
Primary fuse blocks and secondary fuse kits available and easily adaptable
Series-parallel connecting links save wiring and labor costs
Terminal blocks allow full access for ring terminals for easy installation even with solid strand conductors
Integrally molded terminal blocks with isolation barriers to prevent arc over
Copper windings on all groups
Heavy gauge steel mounting plate adapts to various mounting dimensions
Voltage regulation exceeds NEMA requirements
Open coil and core
0.22 x 0.5 in mounting slot
240/416/480/600; 230/400/460/575, 220/380/440/550; 208/500 VAC primary volt
99/120/130; 95/115/125; 91/110/120; 85/100/110 VAC secondary volt
Silicon steel enclosure