CONTROL TRANSFORMER,500VA,220/460/600-11

Control Transformers
462255 MFG #: MT0500L
Siemens
330.36000 / ea
  • Alternate Catalog Number: US2:MT0500L
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: MT0500L
  • Connection Type: Screw
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 5.39 in H x 5.25 in W x 6.67 in D
  • Enclosure Type: IP20
  • EU RoHS Indicator: C
  • Gross Volume Per Pack: 252.00
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 25.2000 lb
  • Gross Weight per Pack Metric: 11.43
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8504314035
  • Height: 6.4000 in
  • Height [Metric]: 16.2560 cm
  • Insulation: Epoxy
  • Length: 8.7000 in
  • Length [Metric]: 22.0980 cm
  • Maximum Amperage Rating: 0.29 A
  • Mounting Type: Slotted
  • Returnable: Y
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL ListedcUL ListedCSA CertifiedANSI Specified
  • Temperature Rating: 55 °C
  • Type: Class MT
  • UNSPSC: 39121026
  • UPC 11: 75455435328
  • UPC 12: 754554353289
  • Width: 5.8000 in
  • Width [Metric]: 14.7320 cm
  • Stock Status: NONSTOCK
  • Brand: Siemens
  • Manufacturer: Siemens
  • Frequency Rating: 50/60 Hz
  • Phase: 1 pH
  • Power Rating: 75 VA
  • Primary Voltage: 240/416/480/600 VAC
  • Secondary Voltage: 99/120/130 VAC
SIEMENS MT0500L 500VA CONTROL TFMR
QTY
  • Features
Features: Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments, Integrally molded barriers, Molded into the trans-former, are difficult to break during wiring, ; VA Rating: 500 VA
Epoxy encapsulated (50 to 750 VA), epoxy resin impregnated (1 to 5 KVA)
Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
Fuse clips (most models), factory mounted for integral fusing on the secondary side to save panel space, save wiring time and save the cost of buying an add-on fuse block or kit
Integrally molded barriers, between terminals and transformer, protect against electrical creepage, up to 30% greater terminal contact area permits low loss connections, extra deep barriers reduce the chance of shorts from frayed leads or careless wiring
Terminals, molded into the transformer, are difficult to break during wiring, a full quarter-inch of thread on the 10-32 terminal screws prevents stripping and pullout
Jumpers supplied, two jumper links are standard with all transformers which can be wired for dual primary voltages
Laminations are built with silicon steel to minimize core losses and to increase optimum performance and efficiency
Insulation materials are of the highest rating available for the temperature class
Robust design
240/416/480/600, 230/400/460/575, 220/380/440/550, 208/500 VAC primary volt
99/120/130, 95/115/125, 91/110/120, 85/100/110 VAC secondary volt
0.29 A max at 240 VAC