Burndy® YA28A3 HYLUG™ YA-A 1-Hole Non-Insulated Compression Lug Without Inspection Window, 4/0 AWG Copper Conductor
Lug Compression Connectors
19636
MFG #: YA28A3
BURNDY®
16.79000
/ ea
- Application: Wire Termination
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: YA28A3
- Color Code: White
- Country of Origin: US
- EU RoHS Indicator: Y
- Gross Weight Per Pack: 0.1200 lb
- Gross Weight per Pack Metric: 0.05
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8535908020
- Height: 0.85 in
- Height [Metric]: 2.1590 cm
- Length: 3.44 in
- Length [Metric]: 8.7376 cm
- Returnable: Y
- Standard: UL 486A-486B
- Sub Brand: HYLUG
- Type: YA-A, Dual Rated
- UNSPSC: 39121405
- UPC 11: 78181075480
- UPC 12: 781810754801
- Voltage Rating: 35,000 V
- Width: 1.17 in
- Width [Metric]: 2.9718 cm
- Stock Status: NORMALLY STOCKED
- Brand: BURNDY®
- Manufacturer: BURNDY®
- Material: Aluminum
BURNDY's compression connectors are designed for reliable and controllable electrical connections. The complete installation is fully inspectable. They are high conductivity copper and operate cooler than the wire on which they are installed. The connectors withstand a wide range of electrical and environmental conditions, including current surges, temperatures, corrosion and vibrations, for a wide variety of applications. These features mean a consistently high quality connection at a low installed cost. Copper compression connectors are manufactured from high-conductivity electrolytic copper. The connectors are normally tinplated, lead-plated, or plated with proprietary BURNDY® brite finish to provide durable long-lasting corrosion resistance. The connector design has been matched to the cable size to provide the necessary physical strength requirements for reliable electrical performance.
- Brochure URL - 10969_DLW12TYBKE584F3Q.pdf(Brochure URL)
- http://www.burndy.com(Seller Home Page URL)
- Install Instructions 1 URL - 10969_XZMWISK35NQ1TEHO.pdf(Install Instructions 1 URL)
- Line Drawing URL - 10969_JCGH6Z7DKRB38ONU.pdf(Line Drawing URL)
- Spec Sheet URL - 10969_GJ62MERCAPIUT8DK.pdf(Spec Sheet URL)
- Tech Drawing URL - SD.073935-01.pdf(Tech Drawing URL)
- Applications
- Features
Wire Termination |
Features: Type YA-A Aluminum Tin-Plated Compression HYLUG Terminals Are Dual-Rated And Designed For Use On Both Aluminum And Copper Conductors From #12 Solid Through 2000 KCMIL, They Are Designed For Heavy Duty Applications To 35 KV, YA-A Terminals Are Prefilled With PENETROX, And Assembled With Color-Coded End Caps, Available With One, Two, And Four-Hole NEMA Tongues, The Aluminum HYLUG Terminals Are Designed For A Permanent Trouble-Free Electrical Termination, Manufactured From High Conductivity, Wrought Aluminum With Heavy Duty Wall Thickness: Provides Maximum Conductivity, Low Resistance And Ductility For An Excellent Combination Of Electrical And Crimp Forming Properties, Electro-Tin Plated: Provides Durable Long Lasting Corrosion Resistance, Internally Bevelled Barrel: Provides Easy Cable Insertion, Meets UL486B 90 DEG C Requirements: Provides A Quality Electrical Dual Connection, Connector Is Clearly Marked With Wire Size, Die Index, Color-Code And The Proper Number And Location Of Crimps: Provides Easy Identification And Tooling Recommendation For A Proper Compression Which Forms A Homogeneous Mass Resulting In An Excellent Electrical Connection, Factory Prefilled With PENETROX Oxide Inhibiting Compound: Oxide Inhibiting Compound Contains Homogeneously Suspended Metallic Particles To Penetrate The Wires Oxides, Establish Electrical Continuity And Forms An Airtight Connection, Color-Coded End Caps Inserted In Barrel End: Prevents Foreign Materials From Entering And Contaminating The Connector Prior To Usage Plus Identifies The Proper Color-Coded Die For A Reliable Connection, UL Listed 90 DEG C, 600 V - 35 KV, Finish: Electro-Tin Plated, Temperature Rating: 90 DEG C, Wire Strip Length: 1-5/8 IN, Tools, Die Set Catalog Number, And (number Of Crimps): Y35, Y39, Y750 Tool, U28ART Die, (2), Y46 Tool, U28ART Die With PUADP-1 Adapter, (2), Color Code: White, Dieless Tools (number Of Crimps): Mechanical: MY29-3, MRC840AL Tool, (2), Hydraulic HYPRESS: Y644HS Tool, (1), Y81KFT, Y81KFTMBH, PAT81KFT-18V Tool, (2), Die Index: 298 |
For die set catalog number and (number of crimps): Y35, Y39, Y750 tool, (2) U28ART die, Y46 tool, (2) U28ART die with PUADP-1 adapter, dieless tools (number of crimps): Mechanical: (2) MY29-3, MRC840AL tool, hydraulic hypress: (1) Y644HS tool, (2) Y81KFT, Y81KFTMBH, PAT81KFT-18V tool, die index: 298 installation tool |
Manufactured from high conductivity, wrought aluminum with heavy duty wall thickness |
Provides maximum conductivity, low resistance and ductility for an excellent combination of electrical and crimp forming properties |
Provides durable long lasting corrosion resistance |
Internally beveled barrel |
Provides easy cable insertion |
Provides a quality electrical dual connection |
Connector is clearly marked with wire size, die index, color-code and the proper number and location of crimps |
Provides easy identification and tooling recommendation for a proper compression which forms a homogeneous mass resulting in an excellent electrical connection |
Factory prefilled with PENETROX® oxide inhibiting compound |
Oxide inhibiting compound contains homogeneously suspended metallic particles to penetrate the wires oxides, establish electrical continuity and forms an airtight connection |
Color coded end caps inserted in barrel end |
Prevents foreign materials from entering and contaminating the connector prior to usage plus identifies the proper color coded die for a reliable connection |
Type YA-A aluminum tin plated compression HYLUG017 terminals are dual rated and designed for use on both aluminum and copper conductors from #12 solid through 2000 kcmil |
They are designed for heavy duty applications to 35 kV |
YA-A terminals are prefilled with PENETROX® and assembled with color coded end caps |
4/0 AWG stranded/solid conductor |
0.44 in hole center to end, 0.74 in hole center to barrel |
Without inspection window |